Triplex 8'x25' Lift Station for
49 Lots • 598gpm
SITE DETAILS
New 49 lot residential subdivision. Due to site topography,
subdivision's sewer terminated at an existing lift station
currently at build-out, thus requiring a larger replacement
lift station. Romtec Utilities was the solution.
Supplied to a 49 Lot Subdivision; 598 GPM @ 118' TDH (duty
point)
THIS ROMTEC UTILITIES SYSTEM
INCLUDED
City specified: ITT
Flygt FMC controller, SCADA system, auxiliary power & odor
control system
Concrete wet well:
fall & confined space entry control, H-20 rated hatch
Pump disconnect panel: with
free air stand, cable hatch
Piping &
accessories: all stainless steel
ITT Flygt pumps:
NP3153 HT, 18 HP
Level monitoring &
control: Primary - ITT Flygt pressure transducer,
Redundant / Back-up - MultiTrode probes w/MTR relays
Concrete valve vault:
H-20 rated hatch, 6" system, check & operational valves,
discharge pressure gauge, by-pass pumping port, dual force main
design
Generator: Cummins
125 kW w/A.T.S., diesel fuel
Building: 20'-8" X
20'-8" split face block Romtec building
Electrical controls:
UL listed
Communication:
telephone alarming, SCADA system
Odor control: Bioxide
chemical feed system