Utica East Ohio Midstream LNG Plant|Kensington, OH|150 GPM - 59' TDH

jweddell50gpm - 100gpm, Eastern, Industrial, Industrial Water, Oil & Gas, Oily Water, Process Water, Stormwater, Stormwater Runoff

Utica East Ohio Midstream needed a new pump stations to handle low flows of stormwater runoff at its new Kensington Plant in Ohio. To responsibly contain potentially hazardous stormwater from the topsoil, this pump station was designed with a double-wall fiberglass wet well with interstitial leak detection. The pumping system also included corrosion resistant components and sensors due to the potential presences of LNGs in the stormwater runoff. Pumps were engineered with 7.5 hp Ebara pumps in a duplex configuration, and a UL listed control panel was supplied with added cable lengths for installation outside of NFPA classified spaces near the pump station.

Marathon Petroleum

Marathon Petroleum|Robinson, IL|75 GPM - 125' TDH

jweddell50gpm - 100gpm, Central, Corrosive/ Caustic Pumping, Industrial, Oil & Gas, Wastewater

The Marathon Petroleum Refinery in Robinson, IL needed this new industrial process water pump station to handle its medium flows of highly acidic water combined with standard wastewater. A precast concrete sump included an interior Tnemec coating to withstand the water chemistry from a refinery testing lab. 11 hp Goulds grinder pumps were designed in a duplex configuration and included a factory epoxy coating to withstand the water chemistry. The pump station piping was designed with stainless steel components, and corrosion resistant floats were included as the liquid level sensing devices.

V.C. Summer Nuclear Station|Jenkinsville, SC|35 GPM - 33.6' TDH

jweddell5gpm - 50gpm, Eastern, Industrial, Industrial Process Water featured, Industrial Water, Power Generation, Process Water

This package lift station was configured to handle low flows of industrial process water used for nuclear power generation. This lift station was one of the earliest systems to be installed during the construction of two new reactors at the plant. Submersible grinder pumps in a duplex configuration and a below grade valve assembly comprise the principal mechanical operations of the station. An outdoor control panel utilizes floats for primary liquid level-sensing, and an autodialer for communications and alarm notification.

Praxair, Inc|East Chicago, IN|1,800 GPM - 33.5' TDH

jweddell1,000gpm - 5,000gpm, Central, Industrial, Industrial Water, Oil & Gas, Wastewater

A liquid hydrogen plant required this large 20’ deep lift station to handle super-high flows of industrial wastewater. In order to provide redundancy and expanded pumping capabilities, triplex submersible centrifugal pumps were specified in the 8’ diameter sump. A large custom valve vault holds the complete 8” valve configurations with triplex discharge piping and force main headers. Two below grade junction boxes hold electrical disconnects to comply with the classified space. An outdoor UL listed control panel uses float controls for primary and backup liquid level-sensing.