City of Laguna Beach

The City of Laguna Beach|Laguna Beach, CA|600 GPM - 77' TDH

jweddell500gpm - 1,000gpm, Collection Systems, Design and Engineering, Grinder Vault, Pacific, Replacements & Retrofits, Slurry/Gritty Water, Wastewater

This high flow wet/dry lift station replacement was installed “in the sand” of Main Beach with three dry pit pumps in a 26-feet-deep precast rectangular vault. Triplex split case pumps, sump pumps, an intake/exhaust fan, lights, valves, stairs, and a mezzanine were all provided in the package. The Allen Bradley PLC control panel, flow transmitter, and junction box are located in a control building. Sophisticated SCADA, 3 levels of redundancy, auxiliary power, and an HDPE wet well are all primary components of this package lift station.

septic to sewer conversion wastewater

Victorville, California Septic Sewer Conversion Wastewater Lift Station

72.7 GPM
9.6′ TDH

jweddell50gpm - 100gpm, Municipal, Now & Future Expansions, Pacific, Public Works, Wastewater, Wastewater Featured

Victorville, California Septic to Sewer Conversion Wastewater Lift Station Wastewater Lift Station Project Assets DESIGN DRAWINGS PANEL DESIGN SITE-PLANS This was a unique project in Victorville, California for a septic to sewer conversion wastewater lift station. Due to environmental concerns with septic systems near the Mojave River, the City of Victorville needed to come up with a solution. The limited number of homes being converted over from septic to the sewer system resulted in very low ...