The Confederated Tribes of the Grande Ronde Community purchased this lift station to meet the medium sewage flows of a new housing development. Submersible solids handling pumps in a duplex configuration are protected from influent by two deflector panels on two inlet lines. A below-grade concrete valve vault provides easy access to the system valves, pressure gauges, actuators, and access ports. An outdoor UL listed control panel is protected by a shelter/shade structure. Liquid level-sensing is accomplished with a conductive probe and backup float controls.