The pump system was designed to meet city stormwater detention requirements, which required new developments to carefully manage runoff. After construction, stormwater must be collected and released at the same rate as it was before the site was developed.
Beaverton, Oregon Commercial Mixed-Use Stormwater Lift Station
400 GPM
17.8′ TDH
Beaverton, Oregon Commercial Mixed-Use Stormwater Lift Station Project Assets DESIGN DRAWINGS PANEL DESIGN SITE-PLANS For this commercial mixed-use stormwater lift station project in Beaverton, Oregon, a new development required a reliable pump system to manage stormwater runoff. Given Beaverton’s heavy rainfall during the winter and spring months, the system needed to be robust and efficient. The development includes a hotel, gas station, and large retail space. Stormwater is collected in an on-site detention pond and ...
Ajax Natural Gas Plant|Wheeler, TX|200 GPM - 50' TDH
This package pump station was designed to meet a low flow of industrial process water with added low flows of industrial stormwater. The dual purposes of this pump station required shaft-driven centrifugal pumps with the motors located above-grade.