Marine Corps Base Camp Pendleton

US Marine Corps Base|Camp Pendleton, CA|1,585 GPM - 25' TDH

jweddell1,000gpm - 5,000gpm, Grinder Vault, Military Installations, Municipal Collection, Pacific, Sewer System Expansion, Slurry/Gritty Water, Wastewater

The Marine Corps Base Camp Pendleton needed this large wet-dry wastewater lift station to replace an existing system to allow the construction of new enlisted quarters. The new lift station included triplex dry-pit pumps to handle super-high flows of sewage from the facilities. An 8’ diameter precast concrete sump collects the sewage. Suction lines connect the sump to a 200-square-foot rectangular dry pit where the pumps, flow meter, and valve assembly are located. This lift station also includes an upstream grinder pit with a Macho Monster sewage grinder to pulverize solids into passable sizes.

U.S. Army Corps of Engineers

U.S. Army Corps of Engineers|Coyote Valley Dam, CA|1,120 GPM - 150' TDH

jweddell1,000gpm - 5,000gpm, Municipal Collection, Pacific, Sewer System Expansion, Wastewater

This unique package wastewater lift station was designed to meet the high sewage flows of this US Army Corps of Engineers managed reservoir and nearby campgrounds. Vertical chopper pumps were engineered above the sump in a precast concrete structure with the above grade valve assembly. Two inlet lines were engineered with extra piping to direct influent toward the bottom of the sump. The structure also contains the UL listed control panel. Float controls were used for liquid level-sensing, and the control panel included soft starters typical for vertical shaft pumps.

City of Arcata

The City of Arcata | Arcata, CA | 2,947 GPM - 34.2' TDH

jweddell1,000gpm - 5,000gpm, Municipal Collection, Municipal Lift Station Replacement, Pacific, Wastewater

This “turnkey” replacement lift station was designed, supplied, and installed to meet super-high sewage flow with infiltration and inflow requirements of a municipal wastewater lift station. Submersible solids-handling pumps in a triplex configuration were installed. The below-grade valve assembly includes plug valves, check valves, ball valves, a pumping port, and a pigging port. The UL listed control panel has an ultrasonic transducer for primary liquid level sensing, redundant float controls, and an autodialer alarm. VFDs were also included in the lift station controls.

City of Santa Barbara|Santa Barbara, CA|1,500 GPM - 66' TDH

jweddell1,000gpm - 5,000gpm, Airports, Pacific, Sewer System Expansion, Wastewater

This lift station serves a large area and was installed at Santa Barbara Municipal Airport as part of a larger project. Two submersible solids handling pumps are supported by a jockey pump that acts as a sump pump for periods of low flow. An impressive control building contains the UL listed control panel, a backup diesel generator and automatic transfer switch, electric meter main, and ferrous chloride odor controls. The electrical controls interface directly with the existing detailed SCADA system used by the Goleta Sanitary District.

Walmart in Gardnerville, Nevada

Walmart|Gardnerville, NV|1,300 GPM - 23.4' TDH

jweddell1,000gpm - 5,000gpm, Detention Ponds, Pacific, Parking Lot Drainage, Stormwater, Stormwater Runoff

A new Walmart Supercenter required this package stormwater pump station to handle runoff from its large impervious parking lot. A good sized detention basin collects the runoff water during a storm event, including from surrounding properties. Ebara submersible pumps then empty the detention pond at a high flow rate through just 45’ of force main into a gravity line that flows to treatment. An outdoor UL listed control panel includes float controls for primary and backup liquid level-sensing and a basic alarm for communications.