This unique package wastewater lift station was designed to meet the high sewage flows of this US Army Corps of Engineers managed reservoir and nearby campgrounds. Vertical chopper pumps were engineered above the sump in a precast concrete structure with the above grade valve assembly. Two inlet lines were engineered with extra piping to direct influent toward the bottom of the sump. The structure also contains the UL listed control panel. Float controls were used for liquid level-sensing, and the control panel included soft starters typical for vertical shaft pumps.
Fresh & Easy Distribution Center|Riverside, CA|170 GPM - 60' TDH
The expansion of this distribution center for Fresh and Easy food products required a package lift station designed to meet medium wastewater flow requirements. This lift station for the 88-acre storage and supply facility uses an inlet line drop bowl to protect submersible solids-handling pumps in a duplex configuration from cascading influent and turbidity. A below-grade valve vault holds all the valves assembly for two, parallel force mains. An outdoor UL listed control panel utilizes float controls for liquid level-sensing and includes an autodialer for communications.
The City of Laguna Beach|Laguna Beach, CA|600 GPM - 77' TDH
This high flow wet/dry lift station replacement was installed “in the sand” of Main Beach with three dry pit pumps in a 26-feet-deep precast rectangular vault. Triplex split case pumps, sump pumps, an intake/exhaust fan, lights, valves, stairs, and a mezzanine were all provided in the package. The Allen Bradley PLC control panel, flow transmitter, and junction box are located in a control building. Sophisticated SCADA, 3 levels of redundancy, auxiliary power, and an HDPE wet well are all primary components of this package lift station.
Santa Barbara County|Goleta, CA|50 GPM - 28' TDH
Santa Barbara County needed this package lift station to replace an existing system serving a residential area next to Goleta Beach. Ebara submersible sewage pumps were engineered in a duplex configuration to alternate starts and create redundancy in the system. Liquid level-sensing also includes redundancy by using Dwyer floats as the primary control device and a Multitrode probe for high-level backup. A UL listed control panel uses a NEMA 4X stainless steel enclosure to be safely located outside of the existing control building.
Laura Chenel?s Ch?vre Cheese Plant|Sonoma, CA|90 GPM - 10.7' TDH
This gourmet goat cheese plant needed two lift stations configured to handle medium wastewater and industrial flows from the new production plant. Submersible solids handling pumps in duplex configurations are protected from turbulence and cascading influent by an inlet line drop bowl. A below-grade valve vault holds the valves, actuators, and junctions to the force main and, on one station, an included cleanout line. An indoor UL listed control panel contains an intrinsically safe barrier for electrical controls in the wet wells. These two systems were installed at grade for low-profiles.